| ... | ... | @@ -528,7 +528,7 @@ possible values or a numeric range. |
|
|
|
|
|
|
|
- `06` (`_C.heatloss_max_change`)
|
|
|
|
|
|
|
|
- `_C.heatloss_max_change` (typical value: $\le 0.1$): allowed
|
|
|
|
- `_C.heatloss_max_change` (typical value: $<0.1$): allowed
|
|
|
|
maximal relative change in the temperature due to the heatloss
|
|
|
|
source term.
|
|
|
|
|
| ... | ... | @@ -577,9 +577,8 @@ possible values or a numeric range. |
|
|
|
from the momentum equation and the induction equation is not
|
|
|
|
solved.
|
|
|
|
|
|
|
|
- `_C.permeability_rel`: relative magnetic permeability
|
|
|
|
$\mu_{rel}$ ($=\mu/\mu_0,\,\mu_0=4\pi\cdot10^{-7}
|
|
|
|
\mathtt{V}\cdot\mathtt{m}^{-1}\cdot\mathtt{A}^{-1}\cdot\mathtt{s}^{-1}$).
|
|
|
|
- `_C.permeability_rel`: relative magnetic permeability $w+10^{-7}$
|
|
|
|
$\mu_{rel}$ ($=\mu/\mu_0,\,\mu_0=4\pi\cdot10^{-7}\mathtt{V}\cdot\mathtt{m}^{-1}\cdot\mathtt{A}^{-1}\cdot\mathtt{s}^{-1}$).
|
|
|
|
|
|
|
|
**Important:** The Gaussian unit system can be mimicked by
|
|
|
|
choosing a value ${\tt \_C.permeability\_rel}=10^7$ so that
|
| ... | ... | |